Manual
Certificate
Video
- 027-81314188
- 2364840384
YNFDJ-1000 battery pack intelligent automatic charging and discharging machine is suitable for automatic battery charging and discharging detection in communication, electric power, rail transit (railroad, high-speed rail, subway, light rail) and other industries. This product integrates battery constant current and constant power discharge, monomer monitoring (optional), and intelligent charging; one machine has multiple functions, reducing enterprise costs, reducing the labor intensity of maintenance personnel, and providing comprehensive scientific testing methods for battery maintenance. It is battery maintenance Good assistant at work.
1. It integrates the four functions of charging, discharging, cell voltage detection and the whole group of activation, with complete functions and multiple functions in one machine.
2. A wide range of charging and discharging voltage and a large single machine current can charge and discharge different types of lead-acid batteries and alkaline batteries. One machine has multiple uses, reducing enterprise costs and reducing the labor intensity of maintenance personnel.
3. The seven-inch color touch LCD, the display effect is clear and beautiful; the full Chinese man-machine dialogue operation interface is easy to read and operate, beautiful and practical, and easy to operate.
4. Constant current discharge, intelligent three-stage automatic charging, real-time online detection of the voltage of each single cell, voltage, current, time, capacity and other parameters can be set, and various tests of the battery pack can be automatically completed according to the set parameters.
5. In the process of charging and discharging, the parameters such as charging and discharging current, voltage, capacity, time and so on can be modified. You can charge and discharge according to the newly modified parameters without exiting the charging and discharging operation. During the charging and discharging process, human intervention can be used to manually terminate the charging and discharging.
6. It has a variety of safety protection measures: the positive and negative polarity of the charging and discharging cable is reversed, the reverse connection indicator light is on and an alarm sound; the charging and discharging current exceeds the set value, the voltage is higher or lower than the set value, the temperature is abnormal, and the equipment It can automatically alarm and stop charging and discharging.
7. You can view the column chart of the single battery in real time, and you can directly view the single curve and the comparison chart with the reference curve after the test.
8. During the test, if the power is suddenly cut off or not used for a long time, the memory data in the host will not be lost. It can save 10 groups of charging, 10 groups of discharging, and 10 groups of online monitoring data; users can query, delete and export to SD card.
9. The upper computer data management software has powerful functions and friendly interface, providing data management, printing, analysis, report statistics, automatic generation of test reports and other functions.
10. With quick connection function, easy to operate and use.
1. Public parameters:
Display method | 7 inch color touch LCD monitor |
Discharge load | Can alloy resistance (good safety) |
Charging unit | Intelligent high frequency switching power supply |
Cooling method | Forced air-cooled |
Battery type | Lead-acid battery, alkaline battery |
Charge and discharge detection method | The battery pack is separated from the original system |
Accuracy of charge and discharge current | (Resolution 0.1A, accuracy 1A) |
Charge and discharge voltage accuracy | (Resolution 10mV, accuracy 0.1V) |
Discharge termination condition | The lower limit of the entire group voltage, the lower limit of the cell voltage (multiple cells can be set), discharge time, discharge capacity, manual termination |
Charge termination condition | The upper limit of the entire group voltage, the upper limit of the individual voltage (multiple sections can be set), charging time, charging capacity, manual termination |
Single voltage monitoring range (optional) | 0.500V~16.00V (resolution 1mV, accuracy 10mV) |
Charge and discharge time | 0~99 hours and 59 minutes can be set |
Number of charge and discharge cycles | 1~9 times can be set |
Charge and discharge interval | 1 minute to 99 hours can be set |
Data storage space | Built-in 256M+ external 4G (standard) SD card, storage location optional |
Alarm generation and safety measures | The positive and negative polarity of the test cable is reversed; the charging and discharging current exceeds the set value; the voltage is higher or lower than the set value; the temperature is abnormal; the fan fails, etc., the device can automatically alarm and stop discharging. |
Data analysis software | Can start the test online and perform real-time monitoring |
Data analysis and printing project | Display and print dynamic data of setting and measured items such as charge and discharge voltage, charge and discharge current, charge and discharge time, charge and discharge capacity, cell capacity, etc. |
Operating temperature | -20~55℃ |
Relative humidity | 90%(40±2℃) |
Atmospheric pressure | (70~106)kPa |
2. Selection parameters:
Product Category | Communication | Electricity | UPS | Wide voltage range type (Customized) | Railway, subway and other industries |
Battery pack voltage type | 48V | 110V/220V | 380V/450V/600V | 10~300V | 10~120V |
MAX charge and discharge current | 50A/100A/150A | 30A/40A/50A/60A/80A/100A | 30A/50A | 0~ 50A | 0~ 100A |
Charge and discharge voltage range | 30~60V | 110V:90~180V 220V:180~260V | 380V:300~450V 450V:380~500V 600V:450~650V | 10~300V | 10~120V |
Number of single cells | Configure according to the actual number of sections (the cell voltage monitoring function can be turned off) | ||||
Power supply | AC:220V | AC:220V | AC:220V | AC:220V | AC:380V |
Charger | AC:380V | AC:380V | AC:380V | AC:380V | AC:380V |
Handling method | Wheel mobile portable | Wheel mobile portable | Wheel mobile portable | Wheel mobile portable | Cabinet fixed installation |
Host size | 590㎜×340㎜×600㎜ | 590㎜×340㎜×600㎜ | 400㎜×500㎜×800㎜ | 770㎜×435㎜×820㎜ | 600㎜×600㎜×1850㎜ |
Host weight | 45 Kg | 45Kg | 50 Kg | 60 Kg | 230Kg |
Packing | Wooden box | ||||
Package weight | 60Kg | 60Kg | 65Kg | 75Kg | 230Kg |
Mode of transport | Railway, automobile transportation |
- Display method
Side
Display screen
Discharge switch
Our company's products are produced in strict accordance with international standards, national standards, and industry and enterprise standards. They have passed professional inspections by national, provincial and municipal electric power research institutes, measurement centers and electric power authorities, and fully passed the ISO9001 international quality management system certification. GB/T19001-2008 quality management system requirements, GB/T24001-2004 environmental management system requirements, GB/T28001-2011 occupational health and safety management system requirements.
-
Pre-sale commitmentWarmly welcome calls and visits
Provide fast and professional response
Timely, serious and reasonable quotation -
Commitment in saleStrictly execute the contract
Professional technical training
Timely and regular return visits -
After-sales servicePunctual delivery with quality and quantity
Take information feedback seriously
Free lifetime technical consultation