Hotline  027-81314188

Solution
Your location:Home > Engineering case > Solution


Common configuration of 35kV high voltage test equipment

AddTime:2021-02-28 15:17:40   Views:299  

Table 1: Substation part

Serial number

Pilot projects

Category

Recommended equipment

1

High voltage cable

The cable fault tester handles the fault point of the faulty cable. Recommended outside the project regulations

YNDL-1006 cable fault tester

The AC withstand voltage test of high-voltage cables is to check whether the cable head that can be processed by the cable meets the requirements of operating voltage. Because the implementation of power frequency withstand voltage is poor, it is recommended to use a variable frequency series resonance experimental device

YNXZ series resonance overall introduction

2

Nuclear phase

Phase check of the line

YNTAG-8600 Wireless High Voltage Nuclear Phaser

3

Insulator

Zero value insulator detection

YNJC-I Insulator Tester

Table 2: Insulating medium (SF6 gas and insulating oil part)

Serial number

Pilot projects

Category

Recommended equipment

1

Insulating oil

Dielectric strength test of insulating oil

YNJY-1001 Insulating Oil Dielectric Strength Tester (Single Cup)

Dielectric loss test of insulating oil

YNYJS-H insulating oil dielectric loss tester

Moisture test for insulating oil

YNYWS-H Insulating Oil Trace Moisture Tester

2

Microcomputer integrated protection device

Inspection of welded joints and airway connections of sealed gas chambers

YNJL-H SF6 quantitative leak detector

Verification and calibration of gas relay

YNMD-H automatic SF6 density relay tester

Test the water content in SF6 gas

YNWS-H SF6 Smart Water Tester

Table 3: Secondary protection part

Serial number

Pilot projects

Category

Recommended equipment

1

CT volt-ampere characteristics

For the 5% or 10% error curve and change of CT, polarity measurement is performed to verify whether it meets the requirements of the protection device.

YNFA-II transformer volt-ampere ratio and polarity comprehensive tester

2

Microcomputer integrated protection device

Test the fixed value of the microcomputer integrated protection device, test the whole group of projects, and test the linkage projects.

YNJB-802 three-phase relay protection tester

Table 4: Oil test part

Serial number

Pilot projects

Category

Recommended equipment

1

Insulation safety tools, transformers, circuit breakers, insulators, etc.

Tests for insulation resistance, absorption ratio, and polarization index of transformers; tests for insulation resistance of insulators and insulating sleeves.

YN-5000 Insulation Resistance Tester

DC leakage test of transformer

YNZGF series DC high voltage generator

Verification and calibration of gas relay

YNGTB series dry test transformer

YNXC/TC test transformer control box (set)

FDB discharge protection ball gap

Dielectric loss measurement of transformers, PT, CT insulation bushings, etc.

YNJS-H anti-interference precision dielectric loss tester

Contamination salt density test on insulators

YNHM-3000 Insulator Ash Density Tester

2

Transformer, PT, CT, fox-killing coil, reactor

Test the coils of transformers, PTs, CTs, reactors, etc. for internal welding defects and for inter-turn interlayer short circuits, as well as measuring the tap position of the transformer.

YNZZ-10A Transformer DC Resistance Tester

Test the transformer's transformation ratio group, PT, single-phase transformer's transformation ratio polarity, etc., to understand whether the change, group, and polarity meet the parallel (series) operation conditions.

YNBC-H automatic ratio tester

Transition time of on-load tap changer, transition resistance test

YNYZ-H transformer on-load tap changer tester

3

High voltage circuit breaker (switch)

In the closed state, measure the contact resistance of the circuit breaker, load switch, etc. to see if it meets the operating conditions.

YNHL-100A loop resistance tester

Test the time characteristics and mechanical characteristics (dynamic characteristics) of high-voltage circuit breakers to understand whether they meet the requirements of system operation.

YNGKC-6F high voltage switch dynamic characteristic tester

For the vacuum test of the vacuum circuit breaker, see if the arc extinguishing conditions are met.

YNZKD-H vacuum switch vacuum tester

4

Zinc oxide arrester

Test the coils of transformers, PTs, CTs, reactors, etc. for internal welding defects and for inter-turn layer short circuits, as well as measurement of transformer tap positions.

YNZZ-40A Transformer DC Resistance Tester

Measure the U1mA and 0.751mA of the zinc oxide arrester to check whether it meets the system operation requirements

YNZGF series DC high voltage generator

Measure resistive current, capacitive current component and full current under AC operating voltage. Judge whether the arrester is running with disease

YNYB-H zinc oxide arrester resistive current tester

Lightning arrester discharge counter test to check whether the counter action is normal

YNFD-H arrester discharge counter calibrator

 

For more information about Yuenenggao products, please click Product Center. Service hotline: 027-81314188, 18627106286.

 

 

 