Obtain the second-level decoration test permit, and can engage in the installation, maintenance or test activities of power facilities with voltage levels below 330 kV.
Serial number | Machine equipment name | Unit | Quantity | Specification | Model Name |
One | High-voltage generating equipment |
| |||
1 | DC high voltage generator | set | 1 | DC:250kV/5mA | YNZGF-250/5 |
2 | Power frequency withstand voltage test device | set | 1 | AC:10kVA/100kV | YNYDJ-10/100 |
3 | Power frequency withstand voltage test device | set | 1 | AC:5kVA/50kV | YNYDJ-5/50 |
4 | Frequency conversion series resonance test complete set | set | 1 | 2000kVA/400kV/5A 30~300Hz | YNXZ-2000/400 |
5 | Induction withstand voltage test device | set | 1 | 5kVA/360V 150Hz | YNSBF-5/360 |
Two | Electrical measuring instruments | ||||
1 | High voltage dielectric loss tester | station | 2 | 1. The medium measurement accuracy is 1% | YNJS-H |
2 | Loop resistance tester | station | 2 | DC:≥100A | YNHL-100A |
3 | Transformer volt-ampere characteristic tester | station | 1 | 2200V/5A | YNFA-II |
4 | Ground Resistance Tester | station | 1 | Inter-frequency method | YNDW-3A |
5 | Capacitance and inductance tester | station | 1 |
| YNRG-H |
6 | Ground continuity tester | station | 1 | DC:10A | YNDT-10A |
7 | Transformer DC Resistance Tester | station | 2 | DC:≥10A | YNZZ-10A |
8 | Transformer ratio tester | station | 1 | Digital 0.5 level | YNBC-H |
9 | Transformer winding deformation tester | station | 1 | Frequency response method | YNRZ-800A |
10 | On-load tap changer tester | station | 1 | I≥1A | YNYZ-H |
11 | Circuit breaker characteristic tester | station | 2 |
| YNGK-6F |
12 | Zinc oxide arrester resistive current tester | station | 1 |
| YNYB-H |
13 | Three-phase relay protection tester | station | 2 | Two groups of three-phase voltage and current | YNJB-1200 |
14 | Transmission line parameter tester | station | 1 | Inter-frequency method | YNXL-Y |
15 | Lightning strike counter calibrator | only | 1 |
| YNFD-H |
16 | Insulation Resistance Tester | station | 2 | DC: 0~5000V 200G(Ω) | YN-5000 |
Three | Oil and gas test equipment | ||||
1 | SF6 leak detector | station | 1 | Sensitivity 1ppmv | XP-1A |
2 | SF6 Gas Moisture Tester | station | 1 |
| YNWS-H |
3 | SF6 gas density calibrator | station | 1 | Accuracy 0.2 level | YNMD-H |
4 | Insulating oil chromatograph | station | 1 |
| YNYSP-2030 |
5 | Insulating oil closed flash point tester | station | 1 |
| YNBS-H |
6 | Insulating oil micro water meter | station | 1 | PPM level | YNYWS-H |
7 | Insulating oil acid value tester | station | 1 |
| YNYSZ-H |
8 | Insulating oil PH tester | station | 1 |
| YNYPH-H |
9 | Automatic dielectric loss measuring instrument for insulating oil | station | 1 |
| YNYJS-H |
10 | Insulating oil dielectric strength tester | station | 1 |
| YNJY-1001 |
Four | Commonly used instruments | ||||
1 | Megohmmeter | only | 2 | DC:2500V | YN2671 |
2 | Megohmmeter | only | 2 | DC:500V | YN2670 |
3 | Digital double clamp phase voltammeter | only | 2 | Measuring current 1mA~5A | SMG2000B |
For more information about Yuenenggao products, please click Product Center. Service hotline: 027-81314188, 18627106286.